dynawo-default-parameters
The dynawo-default-parameters
module defines the default values for all specific parameters of a dynamic simulation run with Dynawo.
Required properties
parametersFile
The parametersFile
property is a required property that defines the path of the main parameters file.
network.parametersFile
The network.parametersFile
property is a required property that defines the path of the network parameters file
solver.parametersFile
The solver.parametersFile
property is a required property that defines the path of the solver parameters file
Optional properties
network.parametersId
The network.parametersId
property is an optional property that defines the set of network parameters. The default value for this property is NETWORK
.
solver.type
The solver.type
property is an optional property that defines the solver used in the simulation. The default value for this property is SIM
. The available com.powsybl.dynawo.simulator.DynawoSimulationParameters.SolverType
values are:
SIM
: the simplified solver (fixed time step solver)IDA
: the IDA solver (variable time step solver)
solver.parametersId
The solver.parametersId
property is an optional property that defines the set of solver parameters. The default value for this property is SIM
.
Examples
YAML configuration:
dynawo-default-parameters:
parametersFile: /home/user/parametersFile
network.parametersFile: /home/user/networkParametersFile
network.parametersId: NETWORK
solver.type: SIM
solver.parametersFile: /home/user/solverParametersFile
solver.parametersId: SIM
XML configuration:
<dynawo-default-parameters>
<parametersFile>/home/user/parametersFile</parametersFile>
<network.parametersFile>/home/user/networkParametersFile</network.parametersFile>
<network.parametersId>NETWORK</network.parametersId>
<solver.type>SIM</solver.type>
<solver.parametersFile>/home/user/solverParametersFile</solver.parametersFile>
<solver.parametersId>SIM</solver.parametersId>
</dynawo-default-parameters>